MID146 Volvo climate control unit fault codes | Truckmanualshub.com (2024)

Deciphering ofMID146 diagnostic trouble codes for Volvo air conditioners/heater/climate control

See also:

  • MID144 Volvo VECU Control Unit Fault Codes
  • MID141 Volvo Dynafleet control unit fault codes

MID 146 PID 170

Parameter:

Cab temperature sensor

Fault:

FMI 3The climate control unit registers the voltage in the temperature sensor circuit above 4.86 V. The sensor is not connected to the control unit.It is possible to short the signal or ground wire to a higher voltage.

FMI 4The climate control unit registers the voltage in the temperature sensor circuit below 0.7 V. The signal wire is shorted to ground or the sensor is faulty.

MID 146 PID 171

Parameter:

Outdoor temperature sensor

Fault:

FMI 3The microclimate control unit registers the voltage in the temperature sensor circuit above 4.9 V. Closing the signal or ground wire to a higher voltage.Thesensormay befaulty.

FMI 4The climate control unit registers the voltage in the temperature sensor circuit below 0.55 V. The signal wire is shorted to ground or the sensor is faulty.

MID 146 SID 2

Parameter:

Air temperature sensor (located between the evaporator and the fan)

Fault:

FMI 3The climate control unit registers the voltage in the temperature sensor circuit above 4.86 V. The sensor is not connected to the control unit.It is possible to short the signal or ground wire to a higher voltage.

FMI 4The climate control unit registers the voltage in the temperature sensor circuit below 0.24 V. The signal wire is shorted to ground or the sensor is faulty.

MID 146 SID 5

Parameter:

Stepper motor control flap external air flow and recirculation

Fault:

FMI 4The climate control unit registers a short to ground.Shorting the signal wire of an electric motor to a lower voltage or ground.

MID 146 SID 6

Parameter:

Stepper motor for controlling air distribution flaps

Fault:

FMI 4The climate control unit registers a short to ground.Shorting the signal wire of an electric motor to a lower voltage or ground.

MID 146 SID 9

Parameter:

Stepper motor to control the air supply to bypass the heat exchanger

Fault:

FMI 4The climate control unit registers a short to ground.Shorting the signal wire of an electric motor to a lower voltage or ground.

MID 146 SID 11

Parameter:

A / C Compressor Clutch

Fault:

FMI 4Shorting the signal wire to a lower voltage or ground circuit.

FMI 5Broken wire mass of the compressor clutch or defective clutch.

MID 146 SID 12

Parameter:

Coolant flow control valve through heat exchanger

Fault:

FMI 3Shorting the signal or ground wire to a higher voltage.

FMI 4Shorting the signal wire to ground.

FMI 5Broken power wire, ground, fuse F32 defective or valve defective.

MID 146 SID 13

Parameter:

Air temperature sensor after heat exchanger

Fault:

FMI 3The climate control unit registers the voltage in the temperature sensor circuit above 4.9 V. The sensor is not connected to the control unit.It is possible to short the signal or ground wire to a higher voltage.

FMI 4The climate control unit registers the voltage in the temperature sensor circuit below 0.24 V. The signal wire is shorted to ground or the sensor is faulty.

MID 146 SID 14

Parameter:

Micro-fan of the air temperature sensor in the cabin (combined with the temperature sensor)

Fault:

FMI 4Shorting the signal wire to a lower voltage or ground.

MID 146 SID 16

Parameter:

Step motors, first phase

Fault:

FMI 3Shorting the signal wire of the corresponding phase of an electric motor to a higher voltage.

MID 146 SID 17

Parameter:

Stepper motors, second phase

Fault:

FMI 3Shorting the signal wire of the corresponding phase of an electric motor to a higher voltage.

MID 146 SID 18

Parameter:

Stepper motors, third phase

Fault:

FMI 3Shorting the signal wire of the corresponding phase of an electric motor to a higher voltage.

MID 146 SID 19

Parameter:

Stepper motors, fourth phase

Fault:

FMI 3Shorting the signal wire of the corresponding phase of an electric motor to a higher voltage.

MID 146 SID 22

Parameter:

Refrigerant pressure sensor in the system

Fault:

FMI 3The microclimate control unit registers a signal with a voltage higher than 4.5 V from the pressure sensor. The signal or ground wire is closed at a higher voltage.

FMI 4The climate control unit registers a signal with a voltage below 0.3 V from a pressure sensor. The signal wire is shorted toground, there is a wire break between the unit and the sensor, or the sensor is not connected to the connector.

MID 146 SID 232

Parameter:

Power supply 5 V. Refrigerant pressure sensor in the system

Fault:

FMI 3The climate control unit registers the sensor supply voltage above 5.5 V. Shorting the signal or ground wire to a higher voltage.

FMI 4The climate control unit registers a short to ground.Shorting the signal wire to a lower voltage or ground.

MID 146 SID 240

Parameter:

Program memory

Fault:

FMI 2Incorrect software, emergency interruption of the programming process, or the climate control unit is faulty.

MID 146 SID 250

Parameter:

SAE J1708 data feed

Fault:

FMI 2Invalid information from other blocks.check fault codes in other control units.

FMI 3The climate control unit registers the voltage above 4.86 V. The closure of the wires of the data channel to a higher voltage.

FMI 4The climate control unit registers the voltage below 0.24 V. The closure of the wires of the data channel to ground.

FMI 12Faulty data channel wires or faulty control unit.

MID 146 SID 253

Parameter:

Gauge EEPROM Memory

Fault:

FMI 2The programming of the block is incorrect or the memory chip is faulty in the control unit.Reprogram the cabin climate control unit.In extreme cases, replace the control unit.

MID 146 PSID 6

Parameter:

The main temperature sensor (located in the control unit and microclimate switches)

Fault:

FMI 3The climate control unit registers the voltage in the temperature sensor circuit above 4.95 V. Closing the signal or ground wire to a higher voltage.Replace climate control unit.

FMI 4The climate control unit registers the voltage in the temperature sensor circuit below 0.05 V. Closing the signal wire to ground.Replace climate control unit.

MID 146 PSID 7

Parameter:

Compensation temperature sensor (located in the control unit and microclimate switches)

Fault:

FMI 3The climate control unit registers the voltage in the temperature sensor circuit above 4.95 V. Closing the signal or ground wire to a higher voltage.Replace climate control unit.

FMI 4The climate control unit registers the voltage in the temperature sensor circuit below 0.05 V. Closing the signal wire to ground.Replace climate control unit.

MID 146 PSID 8

Parameter:

Solar sensor (located in the control unit and microclimate switches)

Fault:

FMI 4The climate control unit registers the voltage in the temperature sensor circuit below 0.05 V. Closing the signal wire to ground.Replace climate control unit.

MID 146 PSID 200

Parameter:

Data Link DisruptionSAE J1587 with engine control unit MID128

Fault:

FMI 12Communication with the engine control unit MID128 has been interrupted for more than 60 seconds.There is no information about the temperature of the coolant and engine speed.The closure or breakage of the data channel SAE J1587.Check the integrity of the data channel, check the trouble codes in the engine control unit.

MID 146 PSID 201

Parameter:

Data Link DisruptionSAE J1587 with car control unit MID144

Fault:

FMI 12Communication with the vehicle control unit MID144 was interrupted for more than 60 seconds.No information about the speed of the car.The closure or breakage of the data channel SAE J1587.Check theintegrity of the data channel, check the trouble codes in the vehicle control unit.

MID 146 PSID 202

Parameter:

Data Link DisruptionSAE J1587 with dashboard control unit MID140

Fault:

FMI 12Communication with the dashboard control unit MID140 was interrupted for more than 60 seconds.No information about outdoor temperature.The closure or breakage of the data channel SAE J1587.Check the integrity of the data channel, check the trouble codes in the dashboard control unit.

MID146 Volvo climate control unit fault codes | Truckmanualshub.com (2024)

References

Top Articles
Latest Posts
Article information

Author: Msgr. Refugio Daniel

Last Updated:

Views: 5952

Rating: 4.3 / 5 (74 voted)

Reviews: 81% of readers found this page helpful

Author information

Name: Msgr. Refugio Daniel

Birthday: 1999-09-15

Address: 8416 Beatty Center, Derekfort, VA 72092-0500

Phone: +6838967160603

Job: Mining Executive

Hobby: Woodworking, Knitting, Fishing, Coffee roasting, Kayaking, Horseback riding, Kite flying

Introduction: My name is Msgr. Refugio Daniel, I am a fine, precious, encouraging, calm, glamorous, vivacious, friendly person who loves writing and wants to share my knowledge and understanding with you.